F9131 Air Conditioner Filter Gas Filtration Test Bench
1. Airflow resistance test
2. Adsorption efficiency/penetration rate
3. Determine desorption
Air flow test |
(1) Air flow range: (0.0625~310) g/s (under standard conditions) (2) Air flow accuracy: ±0.5% |
Measurement of Throttle Body Outlet Pressure | The outlet pressure of the throttle body is measured by a precision vacuum gauge, and its range accuracy is (-0.1~0) MPa, ±0.25% |
Throttle opening measurement | The measurement of the opening degree adopts a photoelectric encoder. Measuring range of photoelectric encoder: (0~110)°Resolution: 5000 P/r |
TPS power supply | DC power supply for TPS (5±0.05) VDC1A |
Active electronic throttle plate drive parameters |
Control signal frequency setting range: 100Hz~2000Hz Control signal duty cycle setting range: 2%~100% Duty cycle control accuracy: 0.2% |
Power supply for electronic throttle body throttle plate drive motor |
Voltage/current range: (0~30)V/(0~10) ADC voltage/current setting value resolution: 10mV/10mA Voltage/current display value resolution: 10mV/10mA |