F9131 Air Conditioner Filter Gas Filtration Test Bench
1. Airflow resistance test
2. Adsorption efficiency/penetration rate
3. Determine desorption
Meet the following criteria
(1) QC/T 32-2006
(2) QC/T 970-2014
(3) QC/T 793-2007
(4) SAE J726-2002
(5)ISO 5011:2000(E)
(6)JB/T 9747-2005
(7) JIS D1612
Technical index
Air flow | Air flow range: (30~3000)m³/h (under standard conditions) |
Air flow accuracy: ±0.5% | |
Stagnation pressure in front of nozzle | Measuring range: (0~110)kPa |
Accuracy: ±0.1% | |
Stagnation temperature in front of nozzle |
Measuring range: (0~50)℃ Accuracy: Class A |
Ash supply device | Ash supply range: (0.5~100)g/min |
Uniformity: the change in the amount of ash added every 5 minutes does not exceed 5% of the average amount of ash added | |
Static pressure and pressure drop |
Measuring range: (0.1~20)kPa accuracy: ±0.1% FS measuring range: (0~6)kPa accuracy: ±0.1% FS static pressure measurement accuracy: ±0.1% FS |
Environmental condition measurement |
Temperature measurement Measuring range: (-20~80)℃ Accuracy: ±0.5℃ Humidity measurement Measuring range: (0~100)% RH accuracy: ±2%RH atmospheric pressure measurement accuracy ≤±0.3kpa |
Absolute filter quality measurement | Measuring range: electronic balance measuring range is 2Kg |
Accuracy: 0.01g | |
Dust ejector | Meet the requirements of QC/T32 standard |
Related products
Contact us
No.58 Zhengliang 4th Road, Daoyi Development Zone, Shenbei New District, Shenyang City
Official website of mobile phone
WeChat official account