Product
Dedicated to innovation and application of testing equipment in environmental measurement, fluid measurement, and microparticle measurement.
+
  • a248d854-de7c-4d13-9c20-e9b4dae68090.jpg

F9131 air conditioner filter gas filtration test bench

Test Project
1. Airflow Resistance Test
2. Adsorption Efficiency/Penetration Rate
3. Determine Desorption

Service Support:

  • Product Description
  • Meet the following standards

    QC/T 795.2-2007 Automotive Air Conditioning Filter Part 2: Gas Filtration Test

    Airflow Flow range: (100~600) m³/h.
    Measurement accuracy: Class 1.5.
    Inlet resistance (measured using a pressure transducer) Range: (0~10) kPa.
    Accuracy: ±0.1%.
    Pollutant inlet pressure measurement (measured using a pressure transducer) Range: (0~1) MPa.
    Accuracy: ±0.1%.
    Inlet system The intake air is filtered using a HEPA high-efficiency filter to remove suspended particles from the introduced air.
    The pipeline is made of corrosion-resistant stainless steel material, and the intake port is straightened with a honeycomb flow straightener to ensure a uniform flow field.
    Pollutant intake mass flow control (for n-butane) A mass flow controller is used to accurately measure and control the mass flow of gas.
    Full-scale flow range: 5 SCCM~30 SLM.
    Control range: (2~100)%FS.
    Accuracy: Ordinary type
    When ≤10 SLM, ±1%FS.
    When >10 SLM, ±2%FS.
    Repeatability: ±0.2%FS.
    Gas concentration analyzer n-butane test
    Measurement range: (0~100) ppm.
    Resolution: 0.01 ppm.
    Accuracy: ≤±3%FS.
    Toluene test
    Measurement range: (0~100) ppm.
    Resolution: 0.01 ppm.
    Accuracy: ≤±3%FS.

     

Keywords:

Related Products

Get a Quote

Note: We will contact you within one business day. Please pay attention to your email.