F9131 Air Conditioner Filter Gas Filtration Test Bench
1. Airflow resistance test
2. Adsorption efficiency/penetration rate
3. Determine desorption
1. Wind tunnel structure: single return type
2. Opening single test section size: 630mm×630mm
3. Velocity range of test section: (0.5-50)m/s
4. Stability of flow rate: ≤0.5%
5. Flow rate uniformity: ≤1%
6. Air flow deflection angle: ≤1°
7. Turbulence degree: ≤0.5%
8. Fan motor power: 55kW
9. Noise: <85dB
10. Dimensions: 13500mm×5670mm×2450mm
11. Test environment temperature: (5-35)℃