F9131 Air Conditioner Filter Gas Filtration Test Bench
1. Airflow resistance test
2. Adsorption efficiency/penetration rate
3. Determine desorption
Wind tunnel structure | Single recirculation |
Opening single test section size | 150mm×150mm |
Velocity range of test section | (0.4-50)m/s |
Stability of flow rate | ≤1.5%. |
Flow rate uniformity | ≤5% when the flow velocity is (0.4-2) m/s |
≤3% when the flow rate is (2-50) m/s | |
Air flow deflection angle: | ≤1° |
Turbulence: | ≤1.5% |
Motor Power: | 5.5kW |
noise: | <85dB |
Dimensions: | 3010mm×1050mm×1620mm |
Test environment temperature: | (15-35)℃ |